Skip to content

Live scan history

What SoundBase keeps of each analyzer’s sweeps while it scans, for how long, at what resolution, and how to keep more.

While an analyzer scans, SoundBase records its sweeps in the background, whether or not anything is showing them. The history views — Persistence, Waterfall, Occupancy, Interference, Time series and Compare — and the hold traces on the Default view all read it, so opening one partway through a scan starts with the history already recorded instead of an empty panel.

  • Every sweep from the last two minutes. Views over windows up to two minutes use every sweep.
  • One-second history for up to an hour. Each second’s sweeps are kept as their highest and average readings, for views that look further back: the waterfall’s 5 min–1 h spans, and Occupancy, Interference, Time series and hold traces over windows longer than two minutes. Because each second keeps its highest reading, those figures can read high but never miss a hit.

History lasts for the session. It is not saved with the project or synced. Closing the project clears it, and an analyzer that stops and starts again begins a fresh history. The main plot’s waterfall follows the selected zone, so switching zones starts it fresh.

History keeps up to 4,096 points per sweep. A sweep with more points than that is stored as 4,096 evenly spaced points across its span, each holding the highest reading among the points it covers, so a narrow carrier never drops out of the history. For example, a 146 MHz span is stored at one point every 36 kHz.

The live trace is not affected: it always draws every point the analyzer sends. No panel is wide enough to show more than 4,096 points, so the difference only shows if you zoom far into the history.

History shares a fixed amount of memory across every analyzer. A slow or narrow analyzer keeps the full two minutes and the full hour. A fast analyzer with many points per sweep may not:

  • When memory runs short, the oldest sweeps of the two-minute history go first, but the last 30 seconds are kept. Then the one-second history goes, oldest first.
  • Analyzers you aren’t viewing give up their history before the ones you are.
  • In an analyzer’s settings, a line under the sweep settings shows what history keeps at the rate it is actually sweeping, for example “At this sweep rate, history keeps 2 min of every sweep and an hour of one-second history.” If the hour doesn’t fit, it says how much does. The line appears once the analyzer has swept twice, and updates after you change its settings.
  • On a history view, the History label in the bottom-right corner shows how much history it holds right now. Hover over it for the stored resolution.
  • An analyzer that draws several traces (antennas, or A–F series) can keep the hour on some traces and not others; the settings line then says how many keep it.

Fewer points per sweep, or a slower sweep, means less data per second, so history lasts longer. On an analyzer that sizes its points from the RBW, a wider RBW means fewer points. A narrower span on a sweep over 4,096 points doesn’t change how long history lasts, but it makes the stored history finer.