Customizing plot settings
Everything the plot draws and how it draws it — ranges, amplitude scale, frequency bars, the IMD heat map, monitoring thresholds, and every overlay color.
Click the gear button in the plot’s control bar (tooltip Plot Settings). The modal is titled Plot Settings for your site’s name and has five tabs. Settings are per site unless noted.
General tab
Section titled “General tab”| Setting | Default | What it does |
|---|---|---|
| Plot minimum (MHz) / Plot maximum (MHz) | 30 / 1000 | Hard bounds of the plot. Raise the maximum to work in DECT, 2.4 GHz, or 5 GHz |
| Zoom increments (MHz) | 5 | Step size of the Zoom In/Out buttons |
| Default start (MHz) / Default stop (MHz) | 470 / 616 | The view the Default Bandwidth reset button returns to |
| Focus bandwidth (MHz) | 3 | Width of the view when you use Focus on a frequency |
| Min amplitude (dBm) / Max amplitude (dBm) | −120 / 0 | The Y-axis range when auto-scale is off |
| View frequency & amplitude readout on hover | on | The readout dot riding each scan trace at your cursor |
| View equipment profile frequency bands | off | Adds a strip showing each in-use profile’s tuning range above the plot |
Frequencies tab
Section titled “Frequencies tab”These display choices are personal (saved per user, applying across your sites):
- Set frequency transparency — 0%, 25% (default), 50%, or 75% transparency for frequency bars.
- Coordinated frequency marker and Candidate frequency marker — how each kind of frequency is drawn. Bandwidth band with center line (default) shades the occupied bandwidth, draws a 1 px line at the center frequency, and fits the name inside the band. The two legacy looks are opt-in: Solid bandwidth block fills the occupied bandwidth with one solid bar, and 1 pixel line draws only a thin line at the center frequency with no name.
- Show frequency names in bars with Set text orientation — Vertical (rotated) (default), Vertical (flipped), or Stacked letters.
- Show frequency overlaps — on by default. Where solid bars overlap and are checked against each other for channel spacing, a high-contrast bracket above the bars connects them across the shared span; the bars start a little below the top of the plot to make room for it. Zoom in further and dashed lines run down the overlap’s edges through the bars. Zoomed far out, overlaps aren’t marked, but hovering one still shows its details. The bars themselves are drawn whole. Hover the marked span to see the overlapping frequencies and, for each pair checked against each other, worst first, their relationship (same group, zone or site, or another site) and how far they overlap. When the list is taller than the window, the smallest overlaps are left out and the tooltip says how many. Turn it off and overlapping bars are drawn plainly, painting over each other, with no marking or overlap tooltip.
IMD tab
Section titled “IMD tab”The IMD heat map paints 2T3O intermodulation density across the spectrum in 225 kHz buckets — quiet buckets cool-colored, IMD pileups hot.
- Show IMD Heat Map — Yes / No (off by default).
- IMD thresholds — a five-handle slider (defaults 10/20/30/40/50 products) dividing the scale into six color bands you can tune per site.
Hovering the heat map strip shows the bucket’s product count.
Monitoring tab
Section titled “Monitoring tab”Sets the amplitude thresholds that color-code measured levels everywhere — the coordination list’s monitoring view, candidate rows, and the Markers panel view.
Drag up to four handles on the −120 to +30 dBm slider (defaults −90 / −65 / −50) and give each resulting band its own color via the swatch above it. Use + to add a threshold and the trash button to remove the selected one.
Colors tab
Section titled “Colors tab”Show/hide checkboxes and color pickers for every overlay: Plot background, Brush, Axes, Range Exclusion, Exclusion Threshold Line, Live Scan Data, plus grouped toggles for DTV Overlays (TV Channels, Public Safety Channels, Astronomy Channels) and Cellular Block Overlays (Cellular Uplink, Cellular Downlink, Guard Bands, LMR/SMR Services).
Colors for new items
Section titled “Colors for new items”Choose the color your new Scan files and Groups start with. Each has three options:
- Cycle through colors (default) — each new item takes the next color that isn’t already in use.
- Always one color — every new item takes the color you pick. A new zone’s or site’s first group does too. Scans plotted together will look the same.
- No color — new groups are grey, and new scans draw in the plot’s neutral color.
This is an account setting, not a site setting: it saves as soon as you change it, applies on all your sites, and isn’t affected by Save, Restore to Defaults, or a locked site. Items that already exist keep their colors. Groups the RF Assistant creates keep their device-type colors.
Saving, defaults, and resetting
Section titled “Saving, defaults, and resetting”- Save — applies to the current site.
- Save as Defaults — after confirming, saves the current settings as the default for all your sites.
- Restore to Defaults — resets all tabs for this site (confirmed with Reset Plot Settings?).