Transfer function

Compare a measurement mic against a reference to see a system’s magnitude, phase, coherence and impulse response. Set up pairs, find the delay, blank low-coherence data, and handle input latency changes. Needs SoundBase Pro.

A transfer function compares what goes into a system (the reference) with what comes out at the mic (the measurement).

Click Transfer in the View picker in the top bar, or press T. Press T again, or click Spectrum, to go back.

The plot becomes three panes, and the meter strip becomes the transfer function strip: the generator, then one card per transfer function.

If you lose SoundBase Pro, the RTA opens on Spectrum. Your Transfer choice comes back when you have Pro again.

  1. Choose your interface, set Channels to 2 or more, and click Start. See Getting audio in.
  2. Click Add transfer function at the end of the strip.

The new card is named Transfer 1 (then Transfer 2, and so on). Harmony picks the lowest-numbered mic as the measurement, and the generator as the reference if it’s there, or else the next mic.

On the card:

  • The name: type in the box to rename the transfer function. Enter, or clicking away, saves it.
  • Mic: the measurement input.
  • Reference: the reference input: another channel, such as a loopback from the console, or Generator.
  • Delay (ms) and Find: see Find the delay.
  • Enabled: turn a transfer function off to stop measuring it without deleting it.
  • Transfer options (⋯): Delete, and a colour for its curves.

Small level bars on the card show the mic and reference levels, with the same time weighting as the meters. Click a card to select it: the selected card’s curves come to the front, it shows the Peak frequency and level of its magnitude, and it’s the one Capture saves. The card also shows its average coherence, such as 87% coh.

If the strip says A transfer function needs two channels. Set Channels to 2 before Start., end the capture, raise Channels and start again.

Up to eight enabled transfer functions are measured at once.

  • Not on this device: the card’s inputs belong to a different interface from the one running. Pick inputs from this device, or start the other one.
  • Generator cannot be the measurement input: the generator can only be the reference.

From top to bottom:

  • Impulse: the impulse response, with time in milliseconds. A clean, single spike near 0 ms means the delay is right.
  • Phase: from −180° to +180°.
  • Magnitude: the level difference between measurement and reference, in dB around 0, with the coherence trace on its own 0 to 100% scale at the right.

Move the pointer over a pane for a readout of each transfer function at that frequency, or that time in the impulse pane. Click to lock it; Esc unlocks it. Ticked transfer function traces draw on the panes too.

Coherence is how much of the mic signal is explained by the reference: high where the measurement is trustworthy, low where noise, reflections or other sources get in. The Coherence blanking slider at the right of the magnitude pane sets a threshold, 20% to start. Wherever coherence is below it, the magnitude and phase curves break and the band is tinted, so you don’t read noise as response. Drag it to change the threshold; a tick on the coherence scale shows where it is.

The measurement only lines up when the reference is delayed by the time sound takes to reach the mic.

  1. Make sure the reference and the mic both have signal.
  2. Click Find on the card.

Harmony measures the delay, sets Delay (ms), and shows how clear the result was: Good, Fair or Weak. Hover the badge for the peak level and polarity. If Weak, check the signal and try again.

If it can’t find a delay, the card says why, for example Not enough audio yet. Try again in a moment., Pair is not on this device, or No delay found. Check the reference signal.

You can also type a delay into Delay (ms), from 0 to 450 ms.

Browsers can change how long they take to deliver input audio, in the middle of a measurement and without warning. Safari does this most. When the reference is the generator, Harmony watches for these changes.

  • A sudden jump is corrected for you, if Correct input latency jumps is ticked. The card says Input latency changed by <n> ms. Corrected. The correction goes into the System offset shown under the delay, so your Delay (ms) stays the acoustic delay. If the mic or speaker really did move, click Undo.
  • A slower change, or any change with correction off, is shown for you to decide. The card shows Delay change found with three choices: Adjust system delay to add the change to the system offset, Find again to measure the delay afresh, or Dismiss to leave things as they are.

While Harmony checks a change before correcting it, the card shows Correcting.

The system offset starts at zero each capture. With the generator as the reference, hover the ? next to Find for advice on references:

For the most stable measurement, use a loopback input as the reference.

In the Transfer view, the control rail has a Transfer section above Display and Metering. The spectrum’s own Averaging and Peak hold sections hide, because they don’t affect transfer functions.

  • FFT size: 4096 to 32768, shown with the length in milliseconds. Larger gives finer frequency detail and a longer impulse response, but updates more slowly. Turn it up in a reverberant room.
  • Mode, Frames and Time constant (s): the transfer function’s own averaging, separate from the spectrum’s. Frames goes from 1 to 64.
  • Correct input latency jumps: see Input latency changes.
  • Magnitude range (±dB): ±10 dB, ±20 dB, ±30 dB or ±40 dB around 0. Phase is always ±180°. This one isn’t kept: it goes back to ±30 dB the next time you open the RTA.

Bands per octave under Display sets the panes’ resolution too. Press V to restart every transfer function’s average.

Select a card, then click Capture (Space) in the Traces sidebar or press Space. The trace keeps the magnitude, phase, coherence and delay, and shows a TF badge. See Traces.