Skip to content

Spectrum analyzer

Read the live spectrum: pick the resolution, set averaging and peak hold, move the scale, choose a channel, and lock the cursor on a frequency.

The spectrum is the RTA’s Spectrum view, in the RTA, RTA + Spectrograph and DB Hidden layouts. Until a capture is running the plot says Start a capture to see the spectrum. See Getting audio in.

  • One curve per input channel, each in its own colour. The selected channel is drawn on top of the others.
  • Frequency along the bottom, on a log scale, and level in dBFS up the side. The scale always spans 80 dB.
  • The peak strip above the plot: for each channel, Peak with the frequency and level of its loudest band right now.
  • Peak hold, if it’s on: a marker at the highest level each band has reached.
  • Traces you’ve captured and ticked in the Traces sidebar. See Traces.

The spectrum is always unweighted, so it shows what’s actually in the room. The Weighting setting changes the meters only.

Click a channel’s meter in the meter strip to select it. The selected meter gets a coloured edge, and its curve comes to the front. The selected channel is also the one Capture saves and the one the spectrograph draws.

In DB Hidden there are no meters to click, so the plot shows channel buttons (Ch 1, Ch 2 …) at its top right instead.

Move the pointer over the plot. A readout follows it with the frequency under the pointer and each channel’s level there, in dBFS, plus dB SPL for a calibrated channel. The readout keeps updating while the pointer sits still.

Click to lock the cursor where it is. A lock icon (Cursor locked) shows in the readout, and the readout stays when the pointer leaves the plot, still following the live level. Click again, or press Esc, to unlock.

The analyzer settings are in the control rail on the left. They’re greyed out until a capture is running. Hover a setting’s name for a short explanation.

  • Resolution: single runs one FFT for the whole spectrum. multi runs a bank of stages, so low frequencies get fine resolution without slowing the top end.
  • Bands per octave: from 1/1 octave to 1/48 octave. Coarser reads like an octave-band analyzer. Finer shows individual tones. This is a display setting: it doesn’t change the measurement.
  • Live style: Bars or Line, for the live channels. Captured traces always draw as lines.
  • Scale top (dB): the top of the vertical scale, from −40 to +40 in 5 dB steps. The span stays at 80 dB, so this slides the window up and down.
  • Mode:
    • FIFO averages a fixed number of recent frames.
    • Exponential weights recent frames more heavily and never fully forgets.
    • Infinite averages everything since the last restart.
  • Frames (FIFO): 1 to 128. More frames give a steadier curve and a slower response. Next to it, Harmony shows how long that many frames covers.
  • Time constant (s) (Exponential): larger is steadier and slower.

Press V to restart the average, for example after you move the mic.

  • Mode: Off, Decay, or Infinite (held for good).
  • Decay (dB/s): how fast a held peak falls once its hold time is up.
  • Hold time (ms): how long a new peak stays at full value before it starts to fall.

The Metering section sets the meters. See Meters.

Your settings are kept in this browser, for this show. Scale top (dB) is the exception: it goes back to its default the next time you open the RTA.